Whole-roof specification
We set out the lifeline with the guardrails, rooflight covers and walkways the roof also needs, so one survey and one handover covers the complete safe route rather than a line on its own.

Horizontal lifeline system · Fall Angel (Universal Safety Systems Ltd)
A horizontal lifeline with reusable polyurethane shock-absorbing posts — EN 795 Type A and C, up to three users, 15 m spans, 200 m runs — installed and certified by Apex as a Fall Angel authorised installer.
RoofAngel is the horizontal lifeline at the centre of the Fall Angel range from Universal Safety Systems. It is certified to EN 795:2012 Type A and Type C and CEN/TS 16415:2013, and to the British BS 8610:2017 and ACR[M]002:2015, with every component validated by SATRA. Up to three users can be on the system at once, over spans of up to 15 m and system lengths of up to 200 m.
The posts are the point of difference. Their patented polyurethane shock absorption keeps end loads below 10 kN in a fall, and the posts are reusable — they don't have to be replaced after a fall arrest event, which keeps the system in service and the cost of an incident down. A pass-through shuttle carries the user over intermediates and corners without unhooking.
RoofAngel is built to go with the rest of the range: GuardAngel fixed, freestanding and wall-mounted guardrails, SkyAngel rooflight protection, WeightAngel weighted anchors and WalkAngel non-slip walkways, which makes it Apex's choice where a roof needs a lifeline, edge protection and a safe route in one specification.
Specifications from Fall Angel (Universal Safety Systems Ltd). Installed and certified by the Fall Protection Division.
| System type | Horizontal lifeline with shock-absorbing posts |
|---|---|
| Users | Up to 3, simultaneous |
| Use | Fall arrest and fall restraint |
| Maximum span | 15 m |
| Maximum system length | 200 m |
| Energy absorption | Patented polyurethane shock-absorbing posts; end loads below 10 kN; posts reusable after a fall arrest |
| Shuttle | Pass-through — intermediates and corners without unhooking |
| Materials | Grade 304 or 316 stainless steel, polyurethane, aluminium; 8 mm 7×7 stainless cable with swaged ends |
| Fixings | S5 seam clamps; structural rivets for composite panels; TPO/PVC-coated bases with sealed penetrations for membranes; chemical anchors for concrete and masonry; stackable bases |
| Inspection | Recommended at least annually (manufacturer); BS 7883 periodic inspection by Apex |
We set out the lifeline with the guardrails, rooflight covers and walkways the roof also needs, so one survey and one handover covers the complete safe route rather than a line on its own.
Fitted by Apex's manufacturer-trained engineers using the Fall Angel base and fixing for the substrate — seam clamp, rivet, coated membrane base or chemical anchor — with penetrations sealed to the roof detail.
Anchors tested at commissioning; Fall Angel's documentation package, Apex's installation certificate, a layout drawing and the first BS 7883 inspection date handed over.
BS 7883 periodic inspection and recertification, with the reusable posts checked and recorded after any fall arrest event.
Contact our Fall Protection team today about your project. We aim to respond within 24 hours.