FallProtec SecuRope Neo Pro

A low-deflection cable lifeline for ground, wall and overhead use — EN 795 Type C, up to four users, 15 m between anchors — installed and certified by Apex as a Fallprotec authorised installer.

What is the FallProtec SecuRope Neo Pro?

SecuRope Neo Pro is Fallprotec's cable lifeline for roofs, walls and overhead structures. It is certified to EN 795:2012 Type C and CEN/TS 16415:2013 for up to four users, and also to BS 8610 — the British standard for anchor systems — and to the North American ASSP/ANSI Z359.6 and CSA Z259.16.

Its defining feature is how it handles a fall. Rather than relying on the end posts alone, energy is absorbed in orientable intermediate anchors along the line, so the cable deflects less under load. That makes SecuRope the system we specify where fall clearance beneath the edge is limited — low parapets, plant decks, mezzanines — and where spans need to run up to 15 m between anchors. The line can be passed without approaching the anchor, so the user stays connected through intermediates.

Fallprotec builds the range around its brackets: standing-seam, sandwich-panel, hot-deck and steel-beam fixings, ground, wall and ceiling configurations, and a QuickSet fall arrester for inclined runs between 30° and 90°. Bespoke solutions come from Fallprotec's own engineering department, which Apex works with directly on unusual structures.

Specifications.

  • EN 795:2012 Type C
  • CEN/TS 16415:2013
  • BS 8610
  • ASSP/ANSI Z359.6 and CSA Z259.16
System typeCable lifeline — ground, wall or ceiling configuration
UsersUp to 4
UseFall arrest, fall restraint; inclined runs 30°–90° with the QuickSet fall arrester
Maximum span15 m between anchors
Energy absorptionOrientable intermediate anchors; off-line and spring absorbers
CableØ 8 mm, 7×7 construction
GlidersOpening, captive and duplex captive gliders; line passable without approaching the anchor
BracketsStanding seam, sandwich panel, hot-deck roof, steel beams; ground, wall and overhead
Made inLuxembourg

Where it suits.

  • Low fall-clearance edges & plant decks
  • Standing-seam & sandwich-panel roofs
  • Hot-deck (warm) flat roofs
  • Steel-beam & overhead structures
  • Walls & inclined runs
  • Industrial, commercial & airport roofs

How we deliver.

Clearance-led design

We measure the fall clearance at every edge the route passes and set anchor spacing and absorber type so the line's deflection in a fall stays within what the clearance allows — the reason SecuRope is chosen in the first place.

Installation to Fallprotec specification

Fitted by Apex's manufacturer-trained engineers with the Fallprotec bracket for the substrate, cable tensioned to specification and intermediates orientated to the route.

Commissioning & handover

Anchors tested at commissioning, with Fallprotec's documentation, Apex's installation certificate, a layout drawing and the first BS 7883 inspection date handed over on the day.

Annual inspection

BS 7883 periodic inspection and recertification of SecuRope systems, including those installed by others, with genuine Fallprotec components for any remedials.

FAQs.

Is Apex a Fallprotec authorised installer?
Yes. Apex is an authorised installer for Fallprotec and has installed SecuRope systems. We also install Fallprotec's SecuRail rigid rail and anchor points.
Why choose SecuRope over a post-absorbing lifeline?
Because its energy absorption sits in the intermediate anchors along the line, the cable deflects less in a fall. Where the drop beneath an edge is short — a low parapet, a mezzanine, a plant deck — that reduced deflection can be the difference between a system that works and one that lets the user reach the ground.
What is the maximum distance between anchors?
Fallprotec rates SecuRope Neo Pro for up to 15 m between anchors. The spacing on a given roof is set by the fall clearance and the number of users, which we confirm at survey.
Can it be used on an inclined roof?
Yes. With the QuickSet fall arrester the line can be run on inclines between 30° and 90°, and intermediate and end anchors are available for horizontal or inclined lifelines.